Infrared Radiometers

1. SIF-111-SS: High Speed, Standard Field of View Infrared Radiometer

The SIF-111 is a fast response model infrared radiometer with a 0.2 second response time. The analog sensor is un-amplified and has a voltage output. The sensor has a 22° half-angle field of view. Typical applications include plant canopy temperature measurement for use in plant water status estimation, phenotyping, phenomics, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies. Sensor includes IP68 marine-grade stainless-steel cable connector 30 cm from head to simplify sensor removal and replacement for maintenance and recalibration. More Details



2. SIF-121-SS: High Speed, Narrow Field of View Infrared Radiometer

The SIF-121 is a fast response model infrared radiometer with a 0.2 second response time. The analog sensor is un-amplified and has a voltage output. The sensor has a 18° half-angle field of view. Typical applications include plant canopy temperature measurement for use in plant water status estimation, phenotyping, phenomics, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies. Sensor includes IP68 marine-grade stainless-steel cable connector 30 cm from head to simplify sensor removal and replacement for maintenance and recalibration. More Details



3. SIF-1H1-SS: High Speed, Horizontal Field of View Infrared Radiometer

The SIF-1H1 is a fast response model infrared radiometer with a 0.2 second response time. The analog sensor is un-amplified and has a voltage output. The unique geometry of the sensor gives a wide 32° half-angle field of view in the horizontal direction with a 13° half-angle field of view in the vertical direction. This enables the user to mount the sensor at shallower angles without seeing above the horizon while maximizing the area measured. Typical applications include plant canopy temperature measurement for use in plant water status estimation, phenotyping, phenomics, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies. Sensor includes IP68 marine-grade stainless-steel cable connector 30 cm from head to simplify sensor removal and replacement for maintenance and recalibration. More Details


4. SI-111-SS: Standard Field of View Infrared Radiometer Sensor

The SI-111 is an unamplified analog sensor with a voltage output. The sensor has a 22° half-angle field of view and a response time of 0.6 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies. Sensor includes IP68 marine-grade stainless-steel cable connector 30 cm from head to simplify sensor removal and replacement for maintenance and recalibration. More Details



5. SI-121-SS: Narrow Field of View Infrared Radiometer Sensor

The SI-121 is an unamplified analog sensor with a voltage output. The sensor has a 18° half-angle field of view and a response time of 0.6 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies. Sensor includes IP68 marine-grade stainless-steel cable connector 30 cm from head to simplify sensor removal and replacement for maintenance and recalibration. More Details



6. SI-131-SS: Ultra-Narrow Field of View Infrared Radiometer Sensor

The SI-131 is an unamplified analog sensor with a voltage output. The sensor has a 14° half-angle field of view and a response time of 0.6 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies. Sensor includes IP68 marine-grade stainless-steel cable connector 30 cm from head to simplify sensor removal and replacement for maintenance and recalibration. More Details



7. SI-1H1-SS: Horizontal Field of View Infrared Radiometer Sensor

The SI-1H1 is an unamplified analog sensor with a voltage output. The unique geometry of the sensor gives a wide 32° half-angle field of view in the horizontal direction with a 13° half-angle field of view in the vertical direction. This enables the user to mount the sensor at shallower angles without seeing above the horizon while maximizing the area measured. The sensor has a response time of 0.6 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies. Sensor includes IP68 marine-grade stainless-steel cable connector 30 cm from head to simplify sensor removal and replacement for maintenance and recalibration. More Details


8. SI-411-SS: SDI-12 Digital Output Standard Field of View Infrared Radiometer Sensor

The SI-411 has an SDI-12 digital output. The sensor has a 22° half-angle field of view and a response time of 0.1 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies. Sensor includes IP68 marine-grade stainless-steel cable connector 30 cm from head to simplify sensor removal and replacement for maintenance and recalibration. More Details



9. SI-421-SS: SDI-12 Digital Output Narrow Field of View Infrared Radiometer Sensor

The SI-421 has an SDI-12 digital output. The sensor has an 18° half-angle field of view and a response time of 0.1 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies. Sensor includes IP68 marine-grade stainless-steel cable connector 30 cm from head to simplify sensor removal and replacement for maintenance and recalibration. More Details




10. SI-431-SS: SDI-12 Digital Output Ultra-Narrow Field of View Infrared Radiometer Sensor

The SI-431 has an SDI-12 digital output. The sensor has a 14° half-angle field of view and a response time of 0.1 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies. Sensor includes IP68 marine-grade stainless-steel cable connector 30 cm from head to simplify sensor removal and replacement for maintenance and recalibration. More Details




11. SI-4H1-SS: SDI-12 Digital Output Horizontal Field of View Infrared Radiometer Sensor

The SI-4H1 has an SDI-12 digital output. The unique geometry of the sensor gives a wide 32° half-angle field of view in the horizontal direction with a 13° half-angle field of view in the vertical direction. This enables the user to mount the sensor at shallower angles without seeing above the horizon while maximizing the area measured. The sensor has a response time of 0.1 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies. Sensor includes IP68 marine-grade stainless-steel cable connector 30 cm from head to simplify sensor removal and replacement for maintenance and recalibration. More Details


12. MI-210: Standard Field of View Infrared Radiometer with Handheld Meter

The MI-210 has a hand-held meter, attached via cable, that displays and stores sensor measurements. The sensor has a 22° half-angle field of view and a response time of 0.6 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies.





13. MI-220: Narrow Field of View Infrared Radiometer with Handheld Meter

The MI-220 has a hand-held meter, attached via cable, that displays and stores sensor measurements. The sensor has a 18° half-angle field of view and a response time of 0.6 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies.





14. MI-230: Ultra-Narrow Field of View Infrared Radiometer with Handheld Meter

The MI-230 has a hand-held meter, attached via cable, that displays and stores sensor measurements. The sensor has a 14° half-angle field of view and a response time of 0.6 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies.





15. MI-2H0: Horizontal Field of View Infrared Radiometer with Handheld Meter

The MI-2H0 has a hand-held meter, attached via cable, that displays and stores sensor measurements. The unique geometry of the sensor gives a wide 32° half-angle field of view in the horizontal direction with a 13° half-angle field of view in the vertical direction. This enables the user to mount the sensor at shallower angles without seeing above the horizon while maximizing the area measured. The sensor has a response time of 0.6 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies.